skip to main content
Tipo de recurso Mostra resultados com: Mostra resultados com: Índice

Polyetheretherketone (PEEK). Part II: application in clinical practice

Pokorný, D ; Fulín, P ; Slouf, M ; Jahoda, D ; Landor, I ; Sosna, A

Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca, 2010-12, Vol.77 (6), p.470-478 [Periódico revisado por pares]

Czech Republic

Texto completo disponível

Citações Citado por
  • Título:
    Polyetheretherketone (PEEK). Part II: application in clinical practice
  • Autor: Pokorný, D ; Fulín, P ; Slouf, M ; Jahoda, D ; Landor, I ; Sosna, A
  • Assuntos: Animals ; Biocompatible Materials ; Humans ; Joint Prosthesis ; Ketones - adverse effects ; Ketones - chemistry ; Polyethylene Glycols - adverse effects ; Polyethylene Glycols - chemistry ; Prostheses and Implants ; Prosthesis Design
  • É parte de: Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca, 2010-12, Vol.77 (6), p.470-478
  • Notas: ObjectType-Article-2
    SourceType-Scholarly Journals-1
    ObjectType-Feature-3
    content type line 23
    ObjectType-Review-1
  • Descrição: Polyetheretherketone (PEEK) is one of the up-to-date organic polymer thermoplastics with applications in orthopaedics and trauma medicine. This study presents a detailed analysis of its tests and applications in clinical medicine. A wide range of PEEK modifications and composites are commercially available, e.g., PEEK-Classix, PEEK-Optima, Endolign and Motis. They differ in their physical properties, which makes them suitable for different applications. Other forms, so-called PEEK bioactive composites, contain beta-tricalcium phosphate and hydroxyapatite. Research in this field is also concerned with the surface finish of this polymer thermoplastic and involves macroporous titanium and hydroxyapatite layers, or treatment with laser for an exactly defined surface structure. The clinical applications of PEEK and its composites include, in addition to components for spinal surgery, osteosynthesis plates, screws, intramedullary nails or external fixators, which are implants still at the stage of prototypes. In this review, attention is paid to the use of PEEK thermoplastics for joint replacement. Mid-term studies involving hundreds of patients have shown that, for instance, the VerSys Epoch Fullcoat Hip System (Zimmer) has a markedly lower stress-shielding effect. Carbon fibre-reinforced (CFR-PEEK) composites are used to make articulating components for total hip replacement. Their convenient properties allow for production of much thinner liners and an enlargement of the femoral head diameter, thus reducing the wear of joint implants. CFR-PEEK composites are particularly effective for hip resurfacing in which the Mitch PCR (Stryker) acetabular component has been used with good results. The MOTIS polymer acetabular cup (Invibio Ltd.) is another example. Further PEEK applications include the construction of finger-joint prostheses (Mathys AG), suture anchors (Stryker) and various kinds of augmentations (Medin). Based on the information obtained, the authors suggest further use for CFR-PEEK composites, such as the construction of articulating liners for total shoulder joint replacement, particularly in reverse shoulder arthroplasty.
  • Editor: Czech Republic
  • Idioma: Tcheco;Inglês

Buscando em bases de dados remotas. Favor aguardar.