skip to main content
Visitante
Meu Espaço
Minha Conta
Sair
Identificação
This feature requires javascript
Tags
Revistas Eletrônicas (eJournals)
Livros Eletrônicos (eBooks)
Bases de Dados
Bibliotecas USP
Ajuda
Ajuda
Idioma:
Inglês
Espanhol
Português
This feature required javascript
This feature requires javascript
Primo Advanced Search
Busca Geral
Busca Geral
Acervo Físico
Acervo Físico
Produção Intelectual da USP
Produção USP
Primo Advanced Search Query Term
Input search text:
Show Results with:
criteria input
Qualquer
Show Results with:
Qualquer
Primo Advanced Search prefilters
Tipo de material:
criteria input
Todos os itens
Busca Geral
Busca Simples
This feature requires javascript
Assessment of proton radiation-induced charge transfer inefficiency in the CCD273 detector for the Euclid Dark Energy Mission
Gow, J. P. D ; Murray, N. J ; Hall, D. J ; Clarke, A. S ; Burt, D ; Endicott, J ; Holland, A. D Beletic, James W ; Holland, Andrew D
SPIE 2012
Sem texto completo
Citações
Citado por
Serviços
Detalhes
Resenhas & Tags
Nº de Citações
This feature requires javascript
Enviar para
Adicionar ao Meu Espaço
Remover do Meu Espaço
E-mail (máximo 30 registros por vez)
Imprimir
Link permanente
Referência
EasyBib
EndNote
RefWorks
del.icio.us
Exportar RIS
Exportar BibTeX
This feature requires javascript
Título:
Assessment of proton radiation-induced charge transfer inefficiency in the CCD273 detector for the Euclid Dark Energy Mission
Autor:
Gow, J. P. D
;
Murray, N. J
;
Hall, D. J
;
Clarke, A. S
;
Burt, D
;
Endicott, J
;
Holland, A. D
Beletic, James W
;
Holland, Andrew D
Notas:
Conference Location: Amsterdam, , Netherlands
Conference Date: 2012-07-01|2012-07-06
Descrição:
Euclid is a medium class mission selected for launch in 2019, with a primary goal to study the dark universe using the weak lensing and baryonic acoustic oscillations techniques. Weak lensing depends on accurate shape measurements, therefore it is beneficial that the effects of radiation-induced charge transfer inefficiency (CTI) in the Euclid CCD over the six year mission are understood and minimised. This paper describes the initial evaluation of the tolerance to radiation induced charge transfer inefficiency (CTI) of the CCD273 produced by e2v technologies plc, making comparisons with the previous CCD selected for Euclid the CCD203. The CCD273 benefits from the inclusion of a charge injection structure for trap suppression and a reduction in the register channel width. The improvement in tolerance to radiation induced serial CTI achieved by reducing the channel width from 50 μm to 20 μm was measured experimentally to be a factor of 1.7, which compares well to a factor of 1.9 found using a charge volume model
Editor:
SPIE
Data de criação/publicação:
2012
Idioma:
Inglês
This feature requires javascript
This feature requires javascript
Voltar para lista de resultados
Anterior
Resultado
20
Avançar
This feature requires javascript
This feature requires javascript
Buscando em bases de dados remotas. Favor aguardar.
Buscando por
em
scope:(USP_PRODUCAO),scope:(USP_EBOOKS),scope:("PRIMO"),scope:(USP),scope:(USP_EREVISTAS),scope:(USP_FISICO),primo_central_multiple_fe
Mostrar o que foi encontrado até o momento
This feature requires javascript
This feature requires javascript