Smartphone application for mechanical quality assurance of medical linear accelerators

Kim, Hwiyoung ; Lee, Hyunseok ; Park, Jong In ; Choi, Chang Heon ; Park, So-Yeon ; Kim, Hee Jung ; Kim, Young Suk ; Ye, Sung-Joon

Physics in medicine & biology, 2017-06, Vol.62 (11), p.N257-N270 [Periódico revisado por pares]

England: IOP Publishing

Texto completo disponível

Citações Citado por
  • Título:
    Smartphone application for mechanical quality assurance of medical linear accelerators
  • Autor: Kim, Hwiyoung ; Lee, Hyunseok ; Park, Jong In ; Choi, Chang Heon ; Park, So-Yeon ; Kim, Hee Jung ; Kim, Young Suk ; Ye, Sung-Joon
  • Assuntos: Mechanical Phenomena ; mechanical QA ; medical linear accelerator ; Particle Accelerators - instrumentation ; Particle Accelerators - standards ; precision ; Quality Control ; Rotation ; Smartphone ; Software
  • É parte de: Physics in medicine & biology, 2017-06, Vol.62 (11), p.N257-N270
  • Notas: Institute of Physics and Engineering in Medicine
    PMB-105124.R1
    ObjectType-Article-1
    SourceType-Scholarly Journals-1
    ObjectType-Feature-2
    content type line 23
  • Descrição: Mechanical quality assurance (QA) of medical linear accelerators consists of time-consuming and human-error-prone procedures. We developed a smartphone application system for mechanical QA. The system consists of two smartphones: one attached to a gantry for obtaining real-time information on the mechanical parameters of the medical linear accelerator, and another displaying real-time information via a Bluetooth connection with the former. Motion sensors embedded in the smartphone were used to measure gantry and collimator rotations. Images taken by the smartphone's high-resolution camera were processed to evaluate accuracies of jaw-positioning, crosshair centering and source-to-surface distance (SSD). The application was developed using Android software development kit and OpenCV library. The accuracy and precision of the system was validated against an optical rotation stage and digital calipers, prior to routine QA measurements of five medical linear accelerators. The system accuracy and precision in measuring angles and lengths were determined to be 0.05  ±  0.05° and 0.25  ±  0.14 mm, respectively. The mean absolute errors (MAEs) in QA measurements of gantry and collimator rotation were 0.05  ±  0.04° and 0.05  ±  0.04°, respectively. The MAE in QA measurements of light field was 0.39  ±  0.36 mm. The MAEs in QA measurements of crosshair centering and SSD were 0.40  ±  0.35 mm and 0.41  ±  0.32 mm, respectively. In conclusion, most routine mechanical QA procedures could be performed using the smartphone application system with improved precision and within a shorter time-frame, while eliminating potential human errors.
  • Editor: England: IOP Publishing