skip to main content

Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors

Dai, X. H ; Lam, D ; Saveri, E

Journal of structural engineering (New York, N.Y.), 2015-11, Vol.141 (11) [Periódico revisado por pares]

American Society of Civil Engineers

Texto completo disponível

Citações Citado por
  • Título:
    Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors
  • Autor: Dai, X. H ; Lam, D ; Saveri, E
  • Assuntos: Technical Papers
  • É parte de: Journal of structural engineering (New York, N.Y.), 2015-11, Vol.141 (11)
  • Descrição: AbstractIn this paper, a group of demountable shear connectors have been developed and tested to assess their potential and suitability in terms of replacing welded shear studs. The experiments showed that these demountable shear connectors can be easily demounted after testing and have similar capacity and behavior to those of welded shear connectors. After the numerical simulation method had been validated against experimental observation, a parametric study was carried out to understand the effect of concrete grades and stud collar sizes on the shear resistance of demountable shear connections. Simple design calculation methods for welded shear connections or anchoring connections provided in European and American standards were checked to the suitability for assessment of this headed demountable shear connector.
  • Editor: American Society of Civil Engineers
  • Idioma: Inglês

Buscando em bases de dados remotas. Favor aguardar.