skip to main content

Avaliação da modulação autonômica cardíaca no processo de enchimento da bexiga em mulheres com incontinência urinária: perspectiva da fisioterapia; Assessment of cardiac autonomic modulation in the bladder filling process of women with urinary incontinence: the perspective of physiotherapy; Evaluación de la modulación autonómica cardiaca en el proceso de llenado de la vejiga en mujeres con incontinencia urinaria: perspectiva de la fisioterapia

Padilha, Juliana Falcão; Braz, Melissa Medeiros; Seidel, Enio Júnior; Mazo, Giovana Zarpellon; Marques, Jefferson Luiz Brum; Marques, Cláudia Mirian De Godoy

Fisioterapia e Pesquisa; Vol. 24 No. 4 (2017); 363-370

Universidade de São Paulo. Faculdade de Medicina 2017-12-12

Acesso online

  • Título:
    Avaliação da modulação autonômica cardíaca no processo de enchimento da bexiga em mulheres com incontinência urinária: perspectiva da fisioterapia; Assessment of cardiac autonomic modulation in the bladder filling process of women with urinary incontinence: the perspective of physiotherapy; Evaluación de la modulación autonómica cardiaca en el proceso de llenado de la vejiga en mujeres con incontinencia urinaria: perspectiva de la fisioterapia
  • Autor: Padilha, Juliana Falcão; Braz, Melissa Medeiros; Seidel, Enio Júnior; Mazo, Giovana Zarpellon; Marques, Jefferson Luiz Brum; Marques, Cláudia Mirian De Godoy
  • Assuntos: Incontinência Urinária; Variabilidade Da Frequência Cardíaca; Sistema Nervoso Autônomo; Fisioterapia; Saúde Da Mulher; Incontinencia Urinaria; Variabilidad De La Frecuencia Cardiaca; Sistema Nervioso Autónomo; Salud De La Mujer; Urinary Incontinence; Heart Rate Variability; Autonomic Nervous System; Physical Therapy; Women’s Health
  • É parte de: Fisioterapia e Pesquisa; Vol. 24 No. 4 (2017); 363-370
  • Descrição: Se comparó el comportamiento del sistema nervioso autónomo, a través de la variabilidad de la frecuencia cardíaca (VFC), durante las fases de llenado vesical de mujeres con y sin incontinencia urinaria (IU). Se aplicó el International Consultation on Incontinence Questionnaire - Short Form, para autodiagnóstico de IU. Para el análisis de la VFC se utilizaron registros de electrocardiograma (ECG), considerándose 6 registros durante el llenado vesical. Para cuantificar la VFC se utilizaron los métodos: dominio del tiempo (milisegundos); frecuencia (Hertz) y medidas no lineales. A estos parámetros se aplicó la transformación logarítmica (Log). En la comparación de promedios de datos normales se utilizó la prueba t y para los datos no normales la prueba de Mann-Whitney. Participaron 64 mujeres (64.8±6.73 años), 33 con IU y 31 continentes. La variable logaritmo de la razón de los componentes LF y HF (LogLH/HF) ha sido significativamente mayor (p
    The behavior of the Autonomic Nervous System, through Heart Rate Variability (HRV), during the bladder filling phases of women with and without urinary incontinence (UI) was compared. The International Consultation on Incontinence Questionnaire - Short Form was applied for UI self-diagnosis. For the HRV analysis, electrocardiogram (ECG) records were used, 6 of them were recorded during bladder filling. To quantify HRV, the following methods were used: time domain (milliseconds); frequency (Hertz) and non-linear measurements. Logarithmic transformation (Log) was applied to these parameters. In the comparison of normal data means, the t-test was applied and the Mann-Whitney test was applied for the non-normal data. The participants consisted of 64 women (64.8±6.73 years), 33 with UI and 31 without. The logarithm of the LF and HF ratio (LogLH/HF) was significantly higher (p
    Comparou-se o comportamento do sistema nervoso autônomo, por meio da variabilidade da frequência cardíaca (VFC), durante as fases de enchimento vesical de mulheres com e sem incontinência urinária (IU). Aplicou-se o International Consultation on Incontinence Questionnaire - Short Form, para autodiagnóstico de IU. Para análise da VFC utilizaram-se registros de eletrocardiograma (ECG), sendo 6 registros durante o enchimento vesical. Para quantificar a VFC utilizaram-se os métodos: domínio do tempo (milissegundos); frequência (Hertz) e medidas não lineares. A estes parâmetros aplicou-se transformação logarítmica (Log). Na comparação de médias de dados normais utilizou-se teste t e para os dados não normais o teste de Mann-Whitney. Participaram 64 mulheres (64,8±6,73 anos), 33 com IU e 31 continentes. A variável logaritmo da razão dos componentes LF e HF (LogLH/HF) foi significativamente maior (p
  • Títulos relacionados: https://www.revistas.usp.br/fpusp/article/view/143461/138130; https://www.revistas.usp.br/fpusp/article/view/143461/138131
  • Editor: Universidade de São Paulo. Faculdade de Medicina
  • Data de criação/publicação: 2017-12-12
  • Formato: Adobe PDF
  • Idioma: Português;Inglês

Buscando em bases de dados remotas. Favor aguardar.