Extubation failure: Upper airway obstruction by chewing gum. A case report

Gonzalez-Anton, D ; Gallice, T ; Borges Da Silva, A ; Carrié, C

Revista espanola de anestesiologia y reanimacion, 2024

Texto completo disponível

Citações Citado por
  • Título:
    Extubation failure: Upper airway obstruction by chewing gum. A case report
  • Autor: Gonzalez-Anton, D ; Gallice, T ; Borges Da Silva, A ; Carrié, C
  • É parte de: Revista espanola de anestesiologia y reanimacion, 2024
  • Notas: ObjectType-Case Study-2
    content type line 59
    SourceType-Reports-1
    ObjectType-Report-1
  • Descrição: Extubation failure can result from different complications, mostly well described in the literature such as laryngeal edema. Airway obstruction by foreign bodies is a less frequent and unexpected complication and its detection remains a challenge to healthcare professionals. In this case-report, we describe a patient admitted in an intensive care unit following a motor vehicle accident and who underwent an extubation failure and tracheostomy placement due to a misdiagnosed obstruction of a foreign body in the upper airway. Thus, screening of foreign bodies should be considered with a careful interpretation of medical imagery and clinical evaluation in these patients. Finally, cuff leak test, ultrasonography and videolaryngoscopy can be important adjuvants to the identification of suspected foreign bodies.