skip to main content
Tipo de recurso Mostra resultados com: Mostra resultados com: Índice

Permeation of Active Ingredient in Pesticide Formulations Through Single-Use and Reusable Chemical-Resistant Gloves

Shaw, Anugrah ; Coleone, Ana Carla ; Machado-Neto, Joaquim

Performance of Protective Clothing and Equipment: 10th Volume, Risk Reduction Through Research and Testing, 2016, p.233-249 [Periódico revisado por pares]

100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959: ASTM International

Texto completo disponível

Citações Citado por
  • Título:
    Permeation of Active Ingredient in Pesticide Formulations Through Single-Use and Reusable Chemical-Resistant Gloves
  • Autor: Shaw, Anugrah ; Coleone, Ana Carla ; Machado-Neto, Joaquim
  • Assuntos: Glove Requirements ; Permeation ; Pesticides
  • É parte de: Performance of Protective Clothing and Equipment: 10th Volume, Risk Reduction Through Research and Testing, 2016, p.233-249
  • Notas: 2016-01-28 - 2016-01-29Tenth Symposium on Performance of Protective Clothing and Equipment: Risk Reduction Through Research and TestingSan Antonio, TX
  • Descrição: In the United States, the Environmental Protection Agency's “Chemical Resistance Category Selection Chart for Gloves” is used to assign glove requirements on product labels for pesticide applicators. These requirements, based on the breakthrough time of solvents, continue to be used as the basis for assigning gloves even though they were intended as a starting point in the 1980s. Recent revisions to the EPA's Label Review Manual state that any waterproof glove can be used for dry and water-based formulations. On the other hand, barrier laminate and ≥15-mil-thick Viton® (Aero Rubber Co., Inc., Tinley Park, IL) gloves are the only two glove materials for formulations that contain >40 % aromatic petroleum distillates or halogenated hydrocarbon solvents. Of these, barrier laminate has limitations in regard to fit and dexterity, and Viton gloves are very expensive. A survey of operators found that they often wear nitrile and neoprene gloves, including single-use gloves that have not been evaluated. The purpose of the study was to measure cumulative permeation through chemical-resistant gloves to support the development of an international performance standard for gloves and to initiate discussion in the United States on the need to simplify glove requirements for pesticide operators. The study was conducted with a recently developed method to evaluate the permeation of active ingredients through five single-use and seven reusable chemical-resistant gloves. Permeation tests were conducted with dilute formulations and concentrates of seven pesticide formulations. The duration time of 15 min was used for tests conducted with concentrates because operators are required to remove the gloves immediately in the case of an accidental spill. Data show low levels of permeation of active ingredients in some formulations with no carrier solvent. Results also indicate that gloves such as those made of reusable nitrile and neoprene can provide good protection against formulations that contain >40 % aromatic petroleum distillates.
  • Editor: 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959: ASTM International
  • Idioma: Inglês

Buscando em bases de dados remotas. Favor aguardar.